GDC (8) Release 3.5
NAME
gdc - operational user interface for gated (8)
SYNOPSIS
gdc
[ -q ]
[ -n ]
[ -c coresize ]
[ -f filesize ]
[ -m datasize ]
[ -s stacksize ]
[ -t seconds ]
command
DESCRIPTION
gdc provides a user-oriented interface for the operation of the
gated (8)
routing daemon. It provides support for starting and
stopping the daemon, for the delivery of signals to manipulate the
daemon when it is operating, for the maintenance and syntax checking
of configuration files, and for the production and removal of state dumps
and core dumps.
gdc
can reliably determine
gated's
running state and produces a reliable
exit status when errors occur, making it advantageous for use in
shell scripts which manipulate
gated.
Commands executed using
gdc
and, optionally, error messages produced by the execution of those
commands, are logged via the same
syslogd (8)
facility which
gated
itself uses, providing an audit trail of operations performed on
the daemon.
If installed as a setuid root program
gdc
will allow non-root users who are members of a trusted group (by
default the
gdmaint
group) to manipulate the routing daemon while denying access
to others. The name of the user is logged along via
syslogd (8)
along with an indication of each command executed, for audit purposes.
The command-line options are:
- -n
- Run without changing the kernel forwarding table. Useful for
testing, and when operating as a route server which does no
forwarding.
- -q
- Run quietly. With this option informational messages which are
normally printed to the standard output are suppressed and error
messages are logged via syslogd (8) instead of being
printed to the standard error output. This is often convenient
when running gdc from a shell script.
- -t seconds
- Specifies the time in seconds which gdc will
spend waiting for gated to complete certain operations,
in particular at termination and startup. By default this value
is set to 10 seconds.
These additional command-line options may be present, depending on the
options used to compile gdc:
- -c coresize
- Sets the maximum size of a core dump a gated started
with gdc will produce. Useful on systems where
the default maximum core dump size is too small for
gated to produce a full core dump on errors.
- -f filesize
- Sets the maximum file size a gated started with
gdc will produce. Useful on systems where the
default maximum file dump size is too small for gated to
produce a full state dump when requested.
- -m datasize
- Sets the maximum size of the data segment of a gated
started with gdc. Useful on systems where the
default data segment size is too small for gated to run.
- -s stacksize
- Sets the maximum size of stack of a gated started with
gdc. Useful on systems where the default maximum
stack size is too small for gated to run.
The following commands cause signals to be delivered to gated
for various purpose:
- COREDUMP
- Sends an abort signal to gated, causing it to terminate with a core dump.
- dump
- Signal gated to dump its current state into the file
/usr/tmp/gated_dump.
- interface
- Signal gated to recheck the interface configuration.
gated normally does this periodically in any event, but
the facility can be used to force the daemon to check interface
status immediately when changes are known to have occured.
- KILL
- Cause gated to terminate ungracefully. Normally useful
when the daemon has hung.
- reconfig
- Signal gated to reread its configuration file,
reconfiguring its current state as appropriate.
- term
- Signal gated to terminate after shutting down all
operating routing protocols gracefully. Executing this command a
second time should cause gated to terminate even if some
protocols have not yet fully shut down.
- toggletrace
- If gated is currently tracing to a file, cause tracing
to be suspended and the trace file to be closed. If
gated tracing is current suspended, cause the trace file
to be reopenned and tracing initiated. This is useful for moving
trace files.
By default gated obtains its configuration from a file
normally named /etc/gated.config.
The gdc program also maintains several other versions of the
configuration file, in particular named:
- /etc/gated.conf+
- The new configuration file. When gdc
is requested to install a new configuration file, this file is
renamed /etc/gated.conf.
- /etc/gated.conf-
- The old configuration file. When gdc
is requested to install a new configuration file, the previous
/etc/gated.conf is renamed to this name.
- /etc/gated.conf--
- The really old configuration file. gdc
retains the previous old configuration file under this
name.
The following commands perform operations related to configuration files:
- checkconf
- Check /etc/gated.conf for syntax errors. This is
usefully done after changes to the configuration file but before
sending a reconfig signal to the currently
running gated, to ensure that there are no errors in the
configuration which would cause the running gated to
terminate on reconfiguration. When this command is used,
gdc issues an informational message indicating
whether there were parse errors or not, and if so saves the error
output in a file for inspection.
- checknew
- Like checkconf except that the new
configuration file, /etc/gated.conf+, is checked
instead.
- newconf
- Move the /etc/gated.conf+ file into place as
/etc/gated.conf, retaining the older versions of the
file as described above. gdc will decline to do
anything when given this command if the new
configuration file doesn't exist or otherwise looks suspect.
- backout
- Rotate the configuration files in the newer direction,
in effect moving the old configuration file to
/etc/gated.conf. The command will decline to perform the
operation if /etc/gated.conf- doesn't exist or is zero
length, or if the operation would delete an existing, non-zero
length /etc/gated.conf+ file.
- BACKOUT
- Perform a backout operation even if
/etc/gated.conf+ exists and is of non-zero length.
- modeconf
- Set all configuration files to mode 664, owner root, group
gdmaint. This allows a trusted non-root user to modify the
configuration files.
- createconf
- If /etc/gated.conf+ does not exist, create a zero length
file with the file mode set to 664, owner root, group gdmaint.
This allows a trusted non-root user to install a new
configuration file.
The following commands provide support for starting and stopping
gated, and for determining its running state:
- running
- Determine if gated is currently running. This is done
by checking to see if gated has a lock on the file
containing its pid, if the pid in the file is sensible and if
there is a running process with that pid. Exits with zero status
if gated is running, non-zero otherwise.
- start
- Start gated. The command returns an error if
gated is already running. Otherwise it executes the
gated binary and waits for up to the delay interval (10
seconds by default, as set with the -t option
otherwise) until the newly started process obtains a lock on the
pid file. A non-zero exit status is returned if an error is
detected while executing the binary, or if a lock is not obtained
on the pid file within the specified wait time.
- stop
- Stop gated, gracefully if possible, ungracefully if not.
The command returns an error (with non-zero exit status) if
gated is not currently running. Otherwise it sends a
terminate signal to gated and waits for up to the delay
interval (10 seconds by default, as specified with the
-t option otherwise) for the process to exit.
Should gated fail to exit within the delay interval it
is then signaled again with a second terminate signal. Should it
fail to exit by the end of the second delay interval it is
signalled for a third time with a kill signal. This should force
immediate termination unless something is very broken. The
command terminates with zero exit status when it detects that
gated has terminated, non-zero otherwise.
- restart
- If gated is running it is terminated via the same
procedure as is used for the stop command above.
When the previous gated terminates, or if it was not
running prior to command execution, a new gated process is
executed using the procedures described for the
start command above. A non-zero exit status is
returned if any step in this procedure appears to have failed.
The following commands allow the removal of files created by the
execution of some of the commands above:
- rmcore
- Removes any existing gated core dump file.
- rmdump
- Removes any existing gated state dump file.
- rmparse
- Removes the parse error file generated when a
checkconf or checknew command
is executed and syntax errors are encountered in the
configuration file being checked.
The following command allows the version information for
gated to be displayed:
- version
- Show the version information for gated. gated
cannot already be running at the time this command is executed. No options
of gdc are used with this command.
FILES
Many of default filenames listed below contain the string %s, which is
replaced by the name with which gated is invoked. Normally this is
gated, but if invoked as gated-test,
gated will by default look for
/etc/gated-test.conf
. These paths may all be changed at
compilation time.
- /etc/gated
- the gated binary. Another popular location is
/usr/local/sbin/gated
.
- /etc/gated.conf
- current gated configuration file.
- /etc/gated.conf+
- newer configuration file.
- /etc/gated.conf-
- older configuration file
- /etc/gated.conf--
- much older configuration file
- /etc/gated.pid
- where gated stores its pid, the default is
/etc/%s.pid
. Another popular location is
/var/run/%s.pid
.
- /usr/tmp/gated_dump
- gated's state dump file, the default is
/usr/tmp/%s_dump
. Another popular location is
/var/tmp/%s_dump
.
- /usr/tmp/gated_parse
- where config file parse errors go, the default is
/usr/tmp/%s_parse
. Another popular location is
/var/tmp/%s_parse
.
- /usr/tmp
- where gated drops its core file. Another popular
location is
/var/tmp
. The core file is usually
core
, but some systems use core.gated
.
AUTHOR
Dennis Ferguson <dennis@ans.net>
SEE ALSO
gated (8),
ospf_monitor (8),
ripquery (8),
routed (8),
route (8)
syslog (8)
GateD Documentation
GateD Configuration Guide
BUGS
Many commands only work when gated is installed in the system
directory it was configured with.
There is not yet any way to tell gdc about
systems which name their core dump other than core
(core.gated is a less common possibility).
COPYRIGHT INFORMATION
Copyright (c) 1996, 1997 The Regents of the University of Michigan
All Rights Reserved
License to use, copy, modify, and distribute this software and its
documentation can be obtained from Merit at the University of Michigan.
This package and associated documentation is Copyright (c)
1990,1991,1992,1993,1994,1995 Cornell University., all rights reserved.
This software contains code that is Copyright (c) 1988 Regents of the
University of California., all rights reserved.;